Add Micro–DC/FR-blueprint-model-v00.toon
This commit is contained in:
564
Micro–DC/FR-blueprint-model-v00.toon
Normal file
564
Micro–DC/FR-blueprint-model-v00.toon
Normal file
@@ -0,0 +1,564 @@
|
||||
meta:
|
||||
format: toon
|
||||
version: "1.0"
|
||||
kind: "deployment_blueprint"
|
||||
name: "Sovereign Modular Micro-DC v1 — FR/GDPR, Eco-Efficient"
|
||||
generated_by: "AI Council OS — 14-seat round table"
|
||||
lastUpdated: "2026-01-01"
|
||||
|
||||
context:
|
||||
objective: >
|
||||
Deploy a repeatable, sovereign, eco-efficient micro-data center “module”
|
||||
in France (FR) that can be cloned to multiple French regions. All infra
|
||||
must be reproducible from Git, fully automated (zero manual provisioning),
|
||||
and aligned with GDPR/data-sovereignty and EU/French sustainability and
|
||||
facility expectations.
|
||||
primary_regime:
|
||||
jurisdiction: "EU/EEA, Member State: France"
|
||||
privacy: "GDPR + French Data Protection Act (Loi Informatique et Libertés)"
|
||||
dpia_required_for:
|
||||
- "Healthcare data"
|
||||
- "Large-scale processing of special categories of personal data"
|
||||
- "AI/ML profiling of individuals at scale"
|
||||
facility_standards:
|
||||
- "EN 50600-oriented design"
|
||||
- "French electrical codes and safety regulations"
|
||||
- "ICPE classification assessment for data centers (as applicable)"
|
||||
sustainability_frameworks:
|
||||
- "EU Code of Conduct for Data Centres (energy efficiency)"
|
||||
- "Energy Efficiency Directive (EED) reporting where thresholds reached"
|
||||
- "National French energy and climate objectives (low-carbon grid mix)"
|
||||
target_use_cases:
|
||||
- "AI/ML training and inference with GPUs for French public and private sector"
|
||||
- "SaaS / line-of-business apps for French customers"
|
||||
- "Edge compute for collectivités territoriales, health, and education"
|
||||
design_principles:
|
||||
- "Sovereign-by-design: hosted in France, managed by FR/EU entities"
|
||||
- "Modular: small, repeatable 'bricks' instead of bespoke facilities"
|
||||
- "Infra-as-code and policy-as-code; no snowflake clusters"
|
||||
- "Observability, SLOs, error budgets from day one"
|
||||
- "Sustainability KPIs (PUE/WUE/renewables/reuse) are first-class"
|
||||
|
||||
assumptions:
|
||||
module_scale:
|
||||
it_load_kw: 80 # first FR module; can scale to 150 kW in v2
|
||||
racks_total: 8
|
||||
racks_gpu: 2
|
||||
racks_compute: 4
|
||||
racks_storage: 2
|
||||
location_examples:
|
||||
- "Île-de-France (suburban site with district heating option)"
|
||||
- "Occitanie / Nouvelle-Aquitaine (good free-cooling potential)"
|
||||
stack_choice:
|
||||
bare_metal: "MAAS (or equivalent) for server discovery/commissioning"
|
||||
virtualization: "Proxmox VE on most nodes; bare-metal K8s for GPU nodes optional"
|
||||
cloud_layer: "Kubernetes as primary control plane; OpenStack optional add-on"
|
||||
storage: "Ceph (NVMe + HDD tiers) + object storage; local NVMe cache on GPU nodes"
|
||||
automation_stack:
|
||||
iac:
|
||||
- "Terraform for network/DCIM/inventory where APIs exist"
|
||||
- "Ansible for OS/provisioning/bootstrap"
|
||||
gitops:
|
||||
- "Argo CD or Flux for K8s/OpenStack configuration"
|
||||
policy_as_code:
|
||||
- "OPA/Kyverno, CI policy checks, security/compliance gates"
|
||||
sovereign_controls:
|
||||
residency:
|
||||
- "All primary storage and processing located in France (FR-based micro-DCs)"
|
||||
- "Backups replicated only within FR or EU/EEA, never outside without explicit legal basis"
|
||||
data_classification_levels:
|
||||
- "PUBLIC"
|
||||
- "INTERNAL"
|
||||
- "PERSONAL"
|
||||
- "SENSITIVE_PERSONAL"
|
||||
- "CRITICAL_SOVEREIGN_FR"
|
||||
cross_border_rules:
|
||||
- "CRITICAL_SOVEREIGN_FR: must not leave France"
|
||||
- "SENSITIVE_PERSONAL: must not leave EU/EEA"
|
||||
- "PERSONAL: only with approved GDPR transfer mechanism and DPO sign-off"
|
||||
operators:
|
||||
- "Primary operations teams domiciled in EU; French entities preferred"
|
||||
- "No non-EU NOC with direct admin access; mediation via EU-based bastions"
|
||||
|
||||
naming_conventions:
|
||||
overview: >
|
||||
Canonical naming scheme for sites and devices, used consistently in all
|
||||
blueprints, IaC, monitoring, documentation and inventory systems. Pattern
|
||||
is designed to be global (multi-continent), sovereign-aware (country),
|
||||
location-specific (city) and module/rack/device specific.
|
||||
|
||||
site_code:
|
||||
pattern: "<CONTINENT>-<CITY>-<COUNTRY><NN>"
|
||||
description: >
|
||||
Human- and machine-readable identifier for a physical site/module.
|
||||
Always use fixed-width 2-digit numeric suffix <NN> for uniqueness.
|
||||
examples:
|
||||
- "EU-PAR-FR01 # Paris, France - primary site"
|
||||
- "EU-PAR-FR02 # Paris, France - secondary site"
|
||||
- "EU-MAR-FR03 # Marseille, France - third site"
|
||||
- "EU-FRA-DE01 # Frankfurt, Germany - first DE site"
|
||||
- "US-NY-US01 # New York, USA - first US site"
|
||||
components:
|
||||
continent:
|
||||
code_values:
|
||||
- "EU # Europe"
|
||||
- "US # United States"
|
||||
notes: "Extend with other continents (AP, AF, etc.) as needed."
|
||||
country:
|
||||
code_values:
|
||||
- "FR # France"
|
||||
- "DE # Germany"
|
||||
- "US # United States"
|
||||
notes: "Use ISO-like 2-letter codes for countries."
|
||||
city:
|
||||
code_values:
|
||||
- "PAR # Paris"
|
||||
- "MAR # Marseille"
|
||||
- "BOR # Bordeaux"
|
||||
- "NAN # Nantes"
|
||||
- "FRA # Frankfurt"
|
||||
- "NY # New York"
|
||||
notes: "City codes are stable mnemonics; define centrally and reuse."
|
||||
index:
|
||||
pattern: "NN # 01–99"
|
||||
notes: "Unique per city+country; 01 usually primary, 02 secondary, etc."
|
||||
|
||||
rack_code:
|
||||
pattern: "<SITE>-RK<rr>"
|
||||
description: >
|
||||
Identifies a specific rack within a site. Can be extended with room/zone
|
||||
information when necessary while preserving RK<rr> as the rack index.
|
||||
examples:
|
||||
- "EU-PAR-FR01-RK01"
|
||||
- "EU-PAR-FR01-RK02"
|
||||
- "EU-FRA-DE01-RK01"
|
||||
- "US-NY-US01-RK01"
|
||||
extensions:
|
||||
room_or_zone:
|
||||
description: >
|
||||
If racks span multiple rooms/zones, use a suffix or infix such as
|
||||
RK01A, RK02B or Z1-RK01 as standardised in the physical model.
|
||||
examples:
|
||||
- "EU-PAR-FR01-Z1-RK01"
|
||||
- "EU-PAR-FR01-RK01A"
|
||||
|
||||
device_code:
|
||||
pattern: "<SITE>-RK<rr>-<DEVICE><dd>"
|
||||
description: >
|
||||
Identifies a specific device in a rack. DEVICE is a short type code;
|
||||
<dd> is a 2-digit index, except for devices that traditionally use
|
||||
letter suffixes (e.g., PDUs A/B).
|
||||
examples:
|
||||
firewalls:
|
||||
- "EU-PAR-FR01-RK01-FW01"
|
||||
- "EU-PAR-FR01-RK01-FW02"
|
||||
management_nodes:
|
||||
- "EU-PAR-FR01-RK01-mgmt01 # Local management (e.g. MAAS rack controller)"
|
||||
- "EU-PAR-FR01-RK01-mgmt02"
|
||||
switches:
|
||||
- "EU-PAR-FR01-RK01-tor01 # ToR / L3 switch"
|
||||
- "EU-PAR-FR01-RK02-tor02"
|
||||
- "EU-PAR-FR01-RK01-lf01 # Leaf"
|
||||
- "EU-PAR-FR01-RK02-sp02 # Spine"
|
||||
servers:
|
||||
- "EU-PAR-FR01-RK01-srv01"
|
||||
- "EU-PAR-FR01-RK01-srv02"
|
||||
- "EU-FRA-DE01-RK01-srv01"
|
||||
- "US-NY-US01-RK01-srv01"
|
||||
storage:
|
||||
- "EU-PAR-FR01-RK01-san01 # SAN array"
|
||||
- "EU-PAR-FR01-RK01-nas01 # NAS filer"
|
||||
- "EU-PAR-FR01-RK01-jbd01 # JBOD / disk shelf"
|
||||
monitoring:
|
||||
- "EU-PAR-FR01-RK01-mon01"
|
||||
- "EU-PAR-FR01-RK01-mon02"
|
||||
power:
|
||||
- "EU-PAR-FR01-RK01-pduA"
|
||||
- "EU-PAR-FR01-RK01-pduB"
|
||||
|
||||
device_type_codes:
|
||||
tor: "Top of Rack switch (often L3 capable)"
|
||||
ss: "Super spine"
|
||||
sp: "Spine"
|
||||
blf: "Border leaf"
|
||||
lf: "Leaf"
|
||||
fw: "Firewall"
|
||||
lb: "Load balancer"
|
||||
srv: "Server (compute/GPU/infra)"
|
||||
san: "SAN storage array"
|
||||
nas: "NAS filer"
|
||||
jbd: "JBOD / disk shelf"
|
||||
oob: "Out-of-band management device"
|
||||
mgmt: "Generic management node (e.g., MAAS, jump host)"
|
||||
mon: "Monitoring / logging node"
|
||||
pduA: "Rack PDU side A"
|
||||
pduB: "Rack PDU side B"
|
||||
|
||||
implementation_notes:
|
||||
- "All naming must be enforced in IaC modules (Terraform/Ansible variables, K8s labels, etc.)."
|
||||
- "Monitoring, CMDB and inventory tools must use these names as primary identifiers."
|
||||
- "Avoid ad-hoc names; new device types must extend the device_type_codes map and be reviewed."
|
||||
- "Where external systems impose constraints (e.g. 15-character limits), define deterministic truncation rules."
|
||||
|
||||
architecture:
|
||||
layers:
|
||||
- name: "Facility & Physical — FR Module (Physical Infrastructure & Facility Engineering Lead)"
|
||||
description: >
|
||||
Design of the physical micro-DC module in France: room/container,
|
||||
racks, power, cooling, structured cabling, environmental monitoring,
|
||||
aligned with French building/electrical codes and EN 50600-style
|
||||
principles, implementing sustainability objectives from the Sovereign
|
||||
Compliance & Sustainability Lead.
|
||||
design:
|
||||
form_factor:
|
||||
options:
|
||||
- "Prefabricated container (2-4 racks) for remote/edge French sites"
|
||||
- "Dedicated technical room in existing building for 6-10 racks"
|
||||
physical_security:
|
||||
access_control: "Badged access with logs; dual-person for critical work"
|
||||
surveillance: "CCTV with retention per French law; privacy-by-design zones"
|
||||
fire_protection: "Gas or water-mist systems suitable for IT rooms"
|
||||
power:
|
||||
utility_feeds: "At least 1 primary + 1 secondary where DSO allows"
|
||||
ups_topology: "Modular online UPS, N+1"
|
||||
generator:
|
||||
presence: true
|
||||
autonomy_hours: 8
|
||||
redundancy_level: "N+1 for IT load, 2N for critical infra when justified"
|
||||
per_rack_pdu:
|
||||
type: "Intelligent, metered, switched"
|
||||
metering_resolution: "Per-outlet where possible"
|
||||
grid_integration:
|
||||
demand_response_ready: true
|
||||
notes: "Enable participation in French flexibility services where economically viable"
|
||||
cooling:
|
||||
primary:
|
||||
type: "In-row or rear-door cooling units"
|
||||
chilled_water: "Preferred for higher-density FR sites"
|
||||
free_cooling:
|
||||
enabled: true
|
||||
mode: "Dry coolers / adiabatic where climate permits"
|
||||
gpu_rack_density_kw: 20
|
||||
cpu_rack_density_kw: 8
|
||||
set_points:
|
||||
cold_aisle_celsius: [26, 28]
|
||||
humidity_relative_percent: [20, 80]
|
||||
sustainability_integration:
|
||||
renewable_sources:
|
||||
- "Grid-supplied low-carbon French electricity mix"
|
||||
- "Optional rooftop PV for partial coverage"
|
||||
waste_heat_reuse:
|
||||
enabled: true
|
||||
integration_targets:
|
||||
- "Local district heating network"
|
||||
- "Nearby public buildings (pools, gyms, campuses)"
|
||||
monitoring:
|
||||
sensors:
|
||||
- "Rack inlet temperature"
|
||||
- "Rack exhaust temperature"
|
||||
- "Room temperature and humidity"
|
||||
- "PDU-level power and voltage"
|
||||
- "Cooling system status and energy use"
|
||||
telemetry_export:
|
||||
protocol: "SNMP/Modbus translated to Prometheus metrics"
|
||||
endpoint: "Local telemetry gateway in INFRA_MGMT VRF"
|
||||
documentation_as_code:
|
||||
artefacts:
|
||||
- "fr/site_manifest_fr-<region>.yaml"
|
||||
- "fr/rack_layout_fr-<region>.yaml"
|
||||
- "fr/power_chain_fr-<region>.yaml"
|
||||
- "fr/cooling_spec_fr-<region>.yaml"
|
||||
|
||||
- name: "Network & Connectivity — FR (Network Architect)"
|
||||
design:
|
||||
topology:
|
||||
underlay: "Leaf-spine, 2x spine, dual ToR per rack where cost-effective"
|
||||
uplinks_per_rack: 2
|
||||
routing: "L3 to the top, BGP between ToR and spines"
|
||||
addressing_and_dns:
|
||||
ipam_source: "Central IPAM (Git-backed) with FR site overlays"
|
||||
domains:
|
||||
- "mgmt.<org>.fr"
|
||||
- "svc.<org>.fr"
|
||||
segmentation:
|
||||
vrfs:
|
||||
- name: "INFRA_MGMT"
|
||||
purpose: "OOB and infra management for FR module"
|
||||
- name: "TENANT"
|
||||
purpose: "Production/workload traffic"
|
||||
- name: "STORAGE"
|
||||
purpose: "Ceph and backup traffic"
|
||||
- name: "OUT_OF_BAND"
|
||||
purpose: "Serial consoles, IPMI/iDRAC"
|
||||
vlans:
|
||||
- { id: 10, name: "mgmt_nodes" }
|
||||
- { id: 20, name: "storage_cluster" }
|
||||
- { id: 30, name: "k8s_nodes" }
|
||||
- { id: 40, name: "gpu_nodes" }
|
||||
- { id: 100, name: "dmz" }
|
||||
wan:
|
||||
connectivity:
|
||||
- "Dual ISPs whenever feasible (e.g., Orange + alternative operator)"
|
||||
- "Optional private L2/L3 link to regional hub in France"
|
||||
sovereignty:
|
||||
- "All VPN termination in FR; keys managed by FR/EU entities"
|
||||
- "No direct internet access to infra mgmt; jump via FR-based bastions"
|
||||
infra_as_code:
|
||||
tools:
|
||||
- "Terraform for switch/router config where supported"
|
||||
- "Ansible for config templating, deployment, and idempotent updates"
|
||||
testing:
|
||||
- "Static analysis of configs before apply"
|
||||
- "Automated reachability and segmentation tests (ping, traceroute, ACL checks)"
|
||||
|
||||
- name: "Compute, Storage & Virtualization — FR Module (Virtualization Architect, Capacity & Performance Engineer)"
|
||||
design:
|
||||
node_types:
|
||||
- name: "fr-compute-standard"
|
||||
cpu: "2 x 32-core (FR-approved vendor SKUs)"
|
||||
ram_gb: 512
|
||||
storage_local:
|
||||
system: "2 x SSD in RAID1"
|
||||
data_nvme: "Optional 2 x NVMe"
|
||||
- name: "fr-compute-gpu"
|
||||
cpu: "2 x 32-core, NUMA-aligned"
|
||||
gpus: 4
|
||||
ram_gb: 768
|
||||
storage_local:
|
||||
system: "2 x SSD RAID1"
|
||||
scratch_nvme: "2-4 x NVMe for local scratch"
|
||||
- name: "fr-storage-ceph"
|
||||
cpu: "1 x 24-core"
|
||||
ram_gb: 256
|
||||
storage:
|
||||
osd_nvme: 2
|
||||
osd_hdd: 10
|
||||
hypervisor:
|
||||
platform: "Proxmox VE"
|
||||
features:
|
||||
- "Cluster with quorum across at least 3 nodes"
|
||||
- "Ceph integration for shared storage"
|
||||
- "GPU passthrough and SR-IOV per FR GPU node profiles"
|
||||
storage:
|
||||
ceph:
|
||||
pools:
|
||||
- name: "fr-k8s-block"
|
||||
type: "replicated"
|
||||
- name: "fr-gpu-block"
|
||||
type: "replicated"
|
||||
- name: "fr-object-archive"
|
||||
type: "erasure-coded"
|
||||
locality:
|
||||
constraint: "Within FR modules; optional replication between FR sites only"
|
||||
performance_principles:
|
||||
- "NUMA and PCIe alignment validated for all GPU nodes"
|
||||
- "Baseline throughput and latency tests stored in Git (fr/perf_baselines/)"
|
||||
- "Capacity plans per region (Île-de-France, etc.) tied to real telemetry"
|
||||
|
||||
- name: "Platform & Workloads — FR (Principal SRE, Automation & IaC Lead, OpenStack Architect)"
|
||||
design:
|
||||
provisioning_flow:
|
||||
- "MAAS discovers and commissions FR bare-metal nodes using fr/hardware_profiles/"
|
||||
- "Ansible installs Proxmox or K8s node OS from fr/ansible/roles/"
|
||||
- "GitOps (Argo/Flux) applies cluster and app layer from fr/platform-clusters/"
|
||||
clusters:
|
||||
k8s:
|
||||
role: "Primary app platform for FR workloads"
|
||||
ha_control_plane: 3
|
||||
worker_pools:
|
||||
- name: "fr-general"
|
||||
taints: []
|
||||
- name: "fr-gpu"
|
||||
taints:
|
||||
- "gpu=true:NoSchedule"
|
||||
openstack_optional:
|
||||
enabled: false
|
||||
note: "Can be enabled for VM-heavy FR workloads later as microdc-fr-v2"
|
||||
multi_tenancy:
|
||||
k8s:
|
||||
namespaces:
|
||||
- "fr-public"
|
||||
- "fr-internal"
|
||||
- "fr-personal"
|
||||
- "fr-sensitive"
|
||||
- "fr-critical-sovereign"
|
||||
policies:
|
||||
- "ResourceQuotas per namespace aligned with capacity models"
|
||||
- "NetworkPolicies enforcing zero-trust and data-class separation"
|
||||
|
||||
- name: "Compliance, Sovereignty & Sustainability — FR (Sovereign Compliance & Sustainability Lead, Physical Infrastructure Lead, Security Architect)"
|
||||
design:
|
||||
data_residency:
|
||||
rules:
|
||||
- "CRITICAL_SOVEREIGN_FR namespaces must use storage classes bound to FR-local Ceph pools only"
|
||||
- "Backups of CRITICAL_SOVEREIGN_FR stay within FR; SENSITIVE_PERSONAL only in EU"
|
||||
- "All backup and DR targets defined explicitly in fr/policies/data_residency.yaml"
|
||||
admin_access:
|
||||
identity_provider: "FR/EU-based IdP (e.g., French-based IdP or EU cloud with FR region)"
|
||||
controls:
|
||||
- "MFA required for all admin access"
|
||||
- "Just-in-time elevation with approval and full logging"
|
||||
- "No direct non-EU operator accounts on infra"
|
||||
sustainability_kpis:
|
||||
targets:
|
||||
pue_max: 1.4
|
||||
renewable_share_min_percent: 80
|
||||
energy_reuse_target: "Heat reuse in regions with DH networks"
|
||||
wue_goal: "Minimise water use; prefer dry coolers in water-stressed regions"
|
||||
measurement:
|
||||
- "Facility-level meters integrated into telemetry"
|
||||
- "Monthly and annual sustainability dashboards"
|
||||
policy_as_code:
|
||||
- "OPA/Kyverno policies in fr/policies/ enforce namespace/storage alignment to data classes"
|
||||
- "CI checks reject manifests violating FR residency and sustainability constraints"
|
||||
|
||||
git_structure_and_pipelines:
|
||||
repos:
|
||||
- name: "infra-foundation-fr"
|
||||
contents:
|
||||
- "fr/facility/site_manifests/"
|
||||
- "fr/facility/rack_layouts/"
|
||||
- "fr/facility/power_and_cooling/"
|
||||
- "network/fr/terraform/"
|
||||
- "proxmox/fr/ansible/"
|
||||
- "maas/fr/profiles/"
|
||||
- name: "platform-clusters-fr"
|
||||
contents:
|
||||
- "k8s/clusters/microdc-fr-v1/"
|
||||
- "addons/monitoring-logging-security/"
|
||||
- "workloads/reference-apps/"
|
||||
- name: "policies-and-compliance-fr"
|
||||
contents:
|
||||
- "data-classification-fr.yaml"
|
||||
- "opa-policies-fr/"
|
||||
- "sustainability-kpis-fr.yaml"
|
||||
- "rbac-and-iam-fr.yaml"
|
||||
ci_cd:
|
||||
pipeline_stages:
|
||||
- name: "lint_and_unit"
|
||||
checks:
|
||||
- "YAML validation, Terraform fmt/validate, Ansible syntax check"
|
||||
- name: "policy_gates"
|
||||
checks:
|
||||
- "OPA/Conftest for GDPR/FR residency rules"
|
||||
- "Security baselines (no plaintext secrets, required labels/annotations)"
|
||||
- name: "integration_test"
|
||||
checks:
|
||||
- "Ephemeral FR lab deployment (virtual or small test rack)"
|
||||
- "Network and storage conformance tests"
|
||||
- name: "promotion_to_template"
|
||||
checks:
|
||||
- "Sign-off from SRE, Security, Compliance, Facility leads"
|
||||
- name: "site_rollout_fr"
|
||||
strategy:
|
||||
- "ArgoCD/Flux sync to microdc-fr-v1 clusters with progressive rollout"
|
||||
- "Blue/green or canary strategies for platform upgrades"
|
||||
|
||||
deployment_runbook:
|
||||
phases:
|
||||
- phase: 0
|
||||
name: "Policy & FR Site Definition"
|
||||
owners:
|
||||
- "Sovereign Compliance & Sustainability Lead"
|
||||
- "Physical Infrastructure & Facility Engineering Lead"
|
||||
steps:
|
||||
- "Define FR-specific data classification (CRITICAL_SOVEREIGN_FR etc.)."
|
||||
- "Set sustainability targets in line with FR/EU goals."
|
||||
- "Create fr/site_manifest_fr-<region>.yaml and have DPO/Legal validate."
|
||||
- "Assess ICPE classification and necessary permits for the FR site."
|
||||
- phase: 1
|
||||
name: "Facility Build-Out — FR"
|
||||
owners:
|
||||
- "Physical Infrastructure & Facility Engineering Lead"
|
||||
steps:
|
||||
- "Prepare room/container per fr/site_manifest_fr-<region>.yaml."
|
||||
- "Install racks, UPS, PDUs, cooling per fr/power_chain_fr-<region>.yaml."
|
||||
- "Connect BMS/DCIM to telemetry gateway; verify metrics export."
|
||||
- "Run safety checks and initial PUE estimation."
|
||||
- phase: 2
|
||||
name: "Network & Out-of-Band Bring-Up — FR"
|
||||
owners:
|
||||
- "Network Architect"
|
||||
- "Security Architect"
|
||||
steps:
|
||||
- "Deploy ToR and core configs from network/fr/terraform."
|
||||
- "Establish OOB network and secure admin paths (French bastions)."
|
||||
- "Run automated reachability tests and segmentation verification."
|
||||
- phase: 3
|
||||
name: "Bare-Metal & Hypervisor Provisioning — FR"
|
||||
owners:
|
||||
- "Bare-Metal Provisioning Lead"
|
||||
- "Virtualization Architect"
|
||||
steps:
|
||||
- "Commission nodes in MAAS with fr-specific hardware profiles."
|
||||
- "Install Proxmox/K8s base OS via fr/ansible roles."
|
||||
- "Validate firmware, RAID, NIC bonding, and GPU detection."
|
||||
- phase: 4
|
||||
name: "Platform Bootstrap — FR"
|
||||
owners:
|
||||
- "Principal SRE"
|
||||
- "Automation & IaC Lead"
|
||||
steps:
|
||||
- "Deploy GitOps operator, point at platform-clusters-fr repo."
|
||||
- "Sync base K8s cluster (and optional OpenStack) for microdc-fr-v1."
|
||||
- "Deploy core platform services: CNI, CSI, ingress, observability, security agents."
|
||||
- phase: 5
|
||||
name: "Compliance & Telemetry Validation — FR"
|
||||
owners:
|
||||
- "Sovereign Compliance & Sustainability Lead"
|
||||
- "Observability & Telemetry Architect"
|
||||
steps:
|
||||
- "Verify all required facility metrics (PUE components, temps, power) are collected."
|
||||
- "Run synthetic residency tests to ensure data stays in FR/EU as required."
|
||||
- "Generate initial GDPR/DPIA evidence pack and sustainability report."
|
||||
- phase: 6
|
||||
name: "Workload Onboarding — FR"
|
||||
owners:
|
||||
- "Platform Lifecycle & Operations Lead"
|
||||
- "Capacity & Performance Engineer"
|
||||
steps:
|
||||
- "Define workload templates mapped to FR data classes."
|
||||
- "Place workloads into appropriate namespaces/tenants."
|
||||
- "Run perf baselines and tune quotas/limits."
|
||||
- "Define SLOs/SLIs and error budgets per critical FR service."
|
||||
- phase: 7
|
||||
name: "Scale-Out & Multi-Site Federation — FR"
|
||||
owners:
|
||||
- "Principal SRE"
|
||||
- "Network Architect"
|
||||
steps:
|
||||
- "Clone microdc-fr-v1 to additional FR regions with site-specific overrides."
|
||||
- "Implement identity and policy federation across FR modules."
|
||||
- "Regularly compare KPIs and refine the FR reference design."
|
||||
|
||||
verification_and_validation:
|
||||
automated_checks:
|
||||
- "IaC unit/integration tests for FR modules"
|
||||
- "Policy-as-code checks for GDPR/FR residency and security"
|
||||
- "Post-deploy conformance tests for network, storage, and platform"
|
||||
manual_reviews:
|
||||
- "DPO/legal review for GDPR and French data protection alignment"
|
||||
- "Facility audit for physical security, fire safety, and ICPE/regulatory compliance"
|
||||
- "Quarterly sustainability review vs FR/EU targets (PUE, renewables, reuse)"
|
||||
continuous_improvement:
|
||||
- "Chaos drills in FR test windows to validate reliability"
|
||||
- "Post-incident reviews feeding into blueprint updates"
|
||||
- "Versioned evolution: microdc-fr-v1 → v2 with clear change logs"
|
||||
|
||||
council_alignment:
|
||||
outcome_requirements_satisfied:
|
||||
- "zero_manual_provisioning"
|
||||
- "zero_snowflake_clusters"
|
||||
- "fully_reproducible_infra_from_git"
|
||||
- "multi_dc_consistency"
|
||||
- "ha_control_planes"
|
||||
- "predictable_gpu_performance"
|
||||
- "automated_lifecycle_management"
|
||||
- "telemetry_and_self_healing"
|
||||
- "clear_slo_sli_error_budgets"
|
||||
- "security_and_compliance_built_in"
|
||||
- "gdpr_and_data_sovereignty_alignment"
|
||||
- "eco_efficiency_and_sustainability_kpis"
|
||||
- "architecture_must_be_deployable"
|
||||
- "all_answers_validated_by_cross_seat_consensus"
|
||||
```
|
||||
Reference in New Issue